Desa MP10T ユーザーズマニュアル

ページ / 60
www.desatech.com
123995-01C
13
INSTALLATION
Continued
OPERATION
PRESSURE TESTING HEATER GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Figure 
14, page 12).
2.  For natural gas open main gas valve locat-
ed on or near gas meter. For propane/LP 
gas open propane/LP supply tank valve.
3.  Make sure control knob of heater is in the 
OFF position.
4.  Check  all  joints  from  equipment  shutoff 
valve to control valve (see Figures 15 or 
LIGHTING 
INSTRUCTIONS
1.  STOP! Read the safety information start-
ing in column 1.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Turn off any electric power to the appli-
ance if service is to be performed.
4.  Turn control knob clockwise 
 to the 
OFF position.
5.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety information starting in column 1. If 
you don’t smell gas, go to the next step.
6.  Thermostat Models: Turn control knob 
counterclockwise 
  to  the  PILOT 
position. Press in control knob for five (5) 
seconds.
 
Manual Models: Press in and turn control 
knob counterclockwise 
 to the PI-
LOT position. Keep control knob pressed 
in for five (5) seconds.
7.  With control knob pressed in, push down and 
release ignitor button. This will light pilot. The 
pilot is attached to the front of burner.
 
Note: You may be running this heater for 
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be 
pressed in for 30 seconds or more. This will 
allow air to bleed from the gas system.
 
If  needed,  keep  pressing  ignitor  button 
until  pilot  lights.  If  ignitor  does  not  light 
pilot,  refer  to  Troubleshooting,  page  18 
or  contact  a  qualified  service  person  or 
gas supplier for repairs. Until repairs are 
made, light pilot with match. See Manual 
Lighting Procedure,
 page 14.
16, page 12). Apply a noncorrosive leak 
detection fluid to all joints. Bubbles form-
ing show a leak.
5.  Correct all leaks at once.
6.  Light  heater  (see  Operation).  Check  all 
other internal joints for leaks.
7.  Turn off heater (see To Turn Off Gas to 
Appliance, page 14).
8.  Replace front panel.
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or   explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must 
be lighted by hand. When lighting the pi-
lot, follow these instructions exactly.
B.  BEFORE  LIGHTING  smell  all  around 
the appliance area for gas. Be sure to 
smell next to the floor because some 
gas is heavier than air and will settle 
on the floor.
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do 
not use any phone in your building.
• Immediately  call  your  gas  supplier 
from a neighbor’s phone. Follow the 
gas supplier’s instructions.
• If you cannot reach your gas supplier, 
call the fire department.
C.  Use only your hand to push in or turn 
the gas control knob. Never use tools. 
If the knob will not push in or turn by 
hand, don’t try to repair it, call a qualified 
service technician. Force or attempted 
repair may result in a fire or explosion.
D.  Do  not  use  this  appliance  if  any  part 
has been under water. Immediately call 
a qualified service technician to inspect 
the appliance and to replace any part of 
the control system and any gas control 
which has been under water.