NI sbRIO-960x
12
ni.com
Connecting the sbRIO Device to a Network
Use a standard Category 5 (CAT-5) or better Ethernet cable to connect the 
RJ-45 Ethernet port to an Ethernet network.
Caution
To prevent data loss and to maintain the integrity of your Ethernet installation, 
do not use a cable longer than 100 m.
If you need to build your own cable, refer to the 
 section for more 
information about Ethernet cable wiring connections.
The host computer communicates with the device over a standard Ethernet 
connection. If the host computer is on a network, you must configure 
the device on the same subnet as the host computer. If neither the host 
computer nor the device is connected to a network, you can connect the 
two directly using a crossover cable.
If you want to use the device on a subnet other than the one the host 
computer is on, first connect the device on the same subnet as the host 
computer. Use DHCP to assign an IP address or reassign a static IP address 
for the subnet where you want it to be and physically move it to the other 
subnet. Refer to the Measurement & Automation Explorer Help for more 
information about configuring the device in Measurement & Automation 
Explorer (MAX).
Table 2.  RS-232 Serial Port Pin Descriptions
Pin
Signal
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI