uline clrco2175 ユーザーズマニュアル

ページ / 19
Prepare Site
3
4 Prepare Site
Your U-Line product has been designed for either free-standing or 
built-in installation. When built-in, your unit does not require 
additional air space for top, sides, or rear. However, the front 
grille must NOT be obstructed and clearance is required for an 
electrical connection in the rear.
IMPORTANT
IMPORTANT
• Unit can NOT be installed behind a closed cabinet door.
• If you would like to align the face of the unit with other adjacent 
cabinet doors, you may need to alter the wall just behind the 
drain connection on the unit to accommodate the drain. 
Cut-Out Dimensions
(CLR)CO21 & CO11 Series
Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease 
in installation and removal of the unit. 24" is the cabinet depth in 
most installations. 
CLR2160 Series
Follow the cut-out drawing The 15-1/4" width allows 1/4" for ease 
in installation and removal of the unit. 24" is the cabinet depth in 
most installations. 
8"
24"
Minimum
24-1/4"
See Electrical
Specifications
for Power Supply
34-1/4"
to
35-1/8"
See Electrical
Specifications
for Power Supply
34-1/4"
to
35-1/8"
15-1/4"
8"
24"
CO29 Series
Follow the cut-out drawing. The 21-1/16" width allows 1/4" for 
ease in installation and removal of the unit. 24" is the counter 
depth in most installations. The unit is 24" deep including the door 
and handle.
IMPORTANT
IMPORTANT
It is extremely important that this unit sits on a level 
surface, as it does not have feet levelers. If it is not level, 
the ice mold will not fill evenly.
8"
24"
Minimum
21-1/16"
See Electrical
Specifications
for Power Supply
Typical
Counter
Height
34-1/4"
to
35-1/8"
Cut-Out
Height
28-5/8"
to
28-7/8"
Filler Panel (Not Provided by U-Line) –
May Be Added Above or Below Unit
to Enclose for a Built-In Look