 Server System SR1680MV Service Guide
17
Figure 16. Removing the Heatsink
Installing the Heatsink
Reverse the steps in 
 to install the heatsink. Make sure you put 
the heatsink in the right direction—you should see the heatsink information when you 
finish the heatsink installation.
Note: Before you put the heatsink on top of the installed processor, do not forget to check if the 
grease is completely on the bottom of the heatsink. Put the two heatsinks with the 16-fin 
side facing the corresponding DIMM group.
System Memory
Each motherboard supports 18 DDR3 1333/1066/800 DIMMs depending on DIMM 
population and each processor supports up to three channels, one channel with three slots. 
Both registered DIMM and unbuffered DIMM modules are supported. One processor 
supports up to 72GB memory when 8GB DIMM is available.
Mixed memory is neither tested nor supported. Non-ECC memory is not tested and is not 
recommended for use in a server environment.
The location of DIMM sockets on the motherboard is shown in Figure 17: