Intel SSDSC2BB600G401 ユーザーズマニュアル

ページ / 19
 
Intel
 SSD DC S3500 Workload Characterization in RAID Configurations 
 
 
 
 
 
 
 
 
December 2013 
 
White Paper 
329903-001US 
 
13 
5.3  RAID 1 Consistency 
Consistency behind a RAID controller is very important because the performance of any 
RAID set is limited by the lowest performing drive. As a RAID set increases in number of 
drives, the probability of any given drive performing poorly increases. Therefore, if the 
model of drive used is inconsistent in its performance, the inconsistency increases with 
the size of the RAID set.  
The Intel
®
 SSD DC S3500 Series drive has shown excellent consistency when used as a 
single drive. Figure 5 illustrates the consistent of DC S3500 in RAID sets. Notice that the 
maximum latency is grouped very tightly for both the two-drive and eight-drive RAID 
sets, indicating there is very little change in consistency as more SSDs are added.  
Figure 5.   RAID 1 Maximum Latency for 2-drive and 8-drive 
Configurations 
  
 
Intel internal testing, October 2013
 
5.4  RAID 1 Performance Conclusions 
RAID 1 is a very good choice for data needing robust replication. The RAID controller 
used shows good bandwidth with low latency causing little to no effect on read and write 
speeds of the SSDs. The linear scaling of read and write performance with additional 
drives shows that adding more drives would provide good ROI in most applications. The 
highest throughput seen in this test was 2300 MB/s during 100% read using eight drives 
with transfer size of 128KB and a queue of 8 per drive. This means the theoretical 
bandwidth limit of the PCIe lanes was not reached (4000 MB/s for x8 PCIe 2.0).  It is 
theoretically possible that more than eight drives could be used and obtain an increase 
in performance, depending on the latency introduced by the necessary SAS expander.  
The consistency of the drives is well demonstrated in these tests and shows that  
Intel SSD DC S3500 Series drives provide high performance with excellent stability, 
even behind a RAID controller.