Page 26
6-4 Initialization After Replacing Parts
Initialization must be performed after replacing the game PC board, Rom or Step
Controls. If initialization is not performed, the game will not function correctly.
During initialization, ensure that the step edges are level.
6-4-1
Adjustment Method (a)
1.
When the power is turned ON the step-lock motor is automatically checked.
The motor check first locks the steps (If not already locked), unlocks, then
locks them again.
Note: Ensure that the test switch is OFF during motor check. Also ensure that
the steps are not touched during the motor check, or the check will not be
performed correctly.
2.
If the first lock is not completed within fifteen
seconds from power up, an error display
screen appears.
If this happens, refer to 
"Adjustment Method (b)", and initialize the
controls. If the error display screen is still
showing after the controls have been
initialized, refer to section 6-4-3, "Handling
Motor Errors".
After the motor check is successful the
attract screen is displayed.
3.
To initialize the controls, Switch the test switch ON while pressing the
service button.
The screen displays the "SWITCH TEST" screen with INITIALIZE
COMPETED flashing, Initialization is completed.
4.
Turn the test switch OFF to return to normal game mode.
MOTOR ERROR 1
PLEASE STEP ADJUST
SWITCH TEST
TEST SW
ON
COIN SW
ON
SERVICE SW
ON
R SELECTION BUTTON
On
DECISION BUTTON
ON
L SELECTION BUTTON
ON
SWING
0000
0000
CENTER
EDGE
0000
0000
CENTER
INITIALIZE COMPLETED
L/R SELECT + DECISION