Vulcan Materials vulcan g36 ユーザーズマニュアル

ページ / 23
F35425 (October 2005)
Page 16 of 23
ENDURANCE SERIES GAS RANGES - SERVICE PROCEDURES AND ADJUSTMENTS
22. With the motor switch and door switch in the
closed position, check for voltage at the motor
input connection. If voltage is available, replace
the motor. If voltage is not available, disconnect
electrical power from the range and check
continuity between the door switch output
connection and motor input connection.
Repair as necessary.
CONVECTION OVEN
SOLENOID CHECK
The convection oven solenoid is mounted between the
gas supply and convection oven burner assembly.
1.
Remove the kick plate as outlined under
COVERS AND PANELS.
2.
Locate the convection oven solenoid.
3.
Place the convection oven power switch in the
ON position. An audible click should occur when
the switch is activated. If the solenoid does not
cycle, check for proper voltage and ground at
the solenoid.
4.
Place the multimeter in the appropriate AC
range (220 volts AC or 120 volts AC). Check
for voltage at the solenoid. If voltage is not
available, check continuity between the power
switch and solenoid.
5.
If voltage is available, shut off electrical power
to the range. Place the multimeter in the
continuity range. Check for continuity between
the solenoid ground connection and a ground.
If continuity is not available, check and repair
ground connections.
6.
If continuity is available, remove the solenoid
and check for solenoid orifice obstruction. See
the procedure REMOVAL OF CONVECTION
OVEN SOLENOID for solenoid removal
instructions.
7.
Reinstall the solenoid.