Vulcan Materials vulcan g36 ユーザーズマニュアル

ページ / 23
F35425 (October 2005)
Page 9 of 23
2.
Remove the two screws securing the oven
burner assembly.
3.
Disconnect gas line to the burner.
4.
Pull the oven burner assembly out of the oven.
5.
Reverse the procedure to install a new oven
burner assembly.
CONVECTION OVEN CONTROL
VALVE/THERMOCOUPLE PILOT
WARNING:  DISCONNECT  THE
ELECTRICAL  POWER  TO  THE
MACHINE  AND  FOLLOW  LOCKOUT /
TAGOUT  PROCEDURES.
WARNING:  SHUT  OFF  THE  GAS  BEFORE
SERVICING  THE  UNIT.
WARNING:  ALL  GAS  JOINTS  DISTURBED
DURING  SERVICING  MUST  BE  CHECKED  FOR
LEAKS.  CHECK  WITH  A  SOAP  AND  WATER
SOLUTION  (BUBBLES).  DO  NOT  USE  AN
OPEN  FLAME.
The control valve is located behind the oven manifold
cover.
1.
Remove the oven manifold cover as outlined
under COVERS AND PANELS.
2.
Remove top burner grates and deflector,
if necessary, to access the control valve.
3.
Disconnect the pilot tubing.
4.
Remove the two screws securing the control
valve to the manifold.
ENDURANCE SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
5.
Remove the kick plate as outlined under
COVERS AND PANELS.
NOTE: Do not kink the capillary tube when straight-
ening the tubing for removal.
6.
Slide the capillary tube and thermocouple out of
the bracket and straighten the tube so that it can
be passed through the holes in the oven liner.
7.
Remove the capillary tube from all routing clips.
8.
Carefully slide the capillary tube and
thermocouple through the holes in the oven.
9.
Remove the control valve, capillary tube and
thermocouple from the unit.
10. Reverse the procedure to install a new control
valve assembly.
NOTE: During installation do not kink the new
capillary tube when feeding it through the holes in the
oven. Excess tubing can be loosely wrapped.