GBD_GBDF SERIES GAS FRYERS 
VULCAN-HART                                                                                                               F-32934 Rev. D (February 2009) 
-7-
 
 
Š
 
National Electrical Code, ANSI/NFPA-70 (latest edition).  Copies may be obtained 
from The National Fire Protection Association, Batterymarch Park, Quincy, 
MA. 02169-7471. 
 
 
Š
 
In the commonwealth of Massachusetts all gas appliances vented through a  
ventilation hood or exhaust system with a damper or with a power means of 
exhaust shall comply with 248 CMR. 
 
 
 
In Canada: 
 
Š
 
Local codes 
 
Š
 
CAN/CSA-B149.1 Natural Gas Installation (latest edition). 
 
Š
 
CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the 
 Canadian Gas Association 178 Rexdale Blvd., Etobicoke, Ontario Canada 
M9W 1R3. 
 
Š
 
CSA C22.1 Canadian Electric Code L4W 5N6. 
 
ASSEMBLY 
 
The fryer must be restrained to prevent tipping and the splashing of hot liquid.  The means 
of restraint may be the manner of installation, such as connection to a battery of 
appliances, installing the fryer in an alcove, or by separate means such as adequate ties. 
 
FLUE CONNECTION 
 
Make the flue connection as follows: 
 
Š
 
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA 
Standard #96 (latest edition), available from the National Fire Protection 
Association, Batterymarch Park, Quincy, MA  02269. 
 
Š
 
Locate the fryer under a hood with adequate connection to an exhaust 
duct.  The hood must extend 6” (15 cm) beyond fryer on both sides. 
 
Š
 
Clearance above the fryer should be adequate for combustion byproducts  
to be removed efficiently. 
 
Š
 
An 18” (46 cm) minimum clearance should be maintained between the flue 
 vent and the filters of the hood venting system. 
 
Š
 
Never make flue connections directly to the fryer. 
 
Š
 
Do not obstruct the flow of the gases from the appliance.  Proper air  
balance should be maintained in the room.