Testing The Gas Supply System
When test pressures exceed 
1
2
 psig (3.45 kPa), the
generator and its individual shutoff valve must be
disconnected from the gas supply piping system.
When test pressures are 
1
2
 psig (3.45 kPa) or less, the
generator must be isolated from the gas supply system
by closing its individual manual shutoff valve.
ELECTRICAL CONNECTIONS (Fig’s. 2-12)
WARNING:  ELECTRICAL AND GROUNDING
CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL
ELECTRICAL CODE ANSI/NFPA-70 (LATEST
EDITION) AND/OR OTHER LOCAL ELECTRICAL
CODES.
WARNING:  DISCONNECT ELECTRICAL POWER
SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING
ON THE CIRCUIT.
Do not connect the steamer to electrical supply until
after gas connections (if applicable) have been made.
All Models
Unless otherwise specified, field wire electrical
connection is to be 120 volts, 60 Hertz, single phase,
with grounding wire.  Connect electrical supply to the
pigtail leads in the supply junction box located next to
the boiler control box for electric generators in a 24"
wide base, and under the boiler control box for all other
generator bases.  The supply junction box is located on
the underside of the cabinet top on direct steam
models.  Use copper wire suitable for at least 75
°
C
temperature.  A grounding wire must be connected to
the ground lug in the junction box.
When optional step down transformer is used on
electrically heated generators, the 120 volt connection
is not required.
Electrically Heated Generators
Make the electrical supply connection in the junction
box on the contactor box.  The supply wiring and circuit
protection must be adequate for the kilowatt load drawn
by the cooker.  A grounding wire must be connected to
the ground lug in the junction box.  Use copper wire of
the size and temperature rating marked on the supply
label.
DRAIN CONNECTIONS (Fig’s. 2-12)
Drain connections must be the open air gap type.
Provide a suitable drain under the drain pipes.  For
proper drainage, a floor sink with minimum of 12" depth
is recommended.
CAUTION:  In order to avoid any back pressure in
the steamer, do not connect solidly to any drain
connection.
PLUMBING CONNECTIONS (Fig’s. 2-12)
WARNING:  PLUMBING CONNECTIONS MUST
COMPLY WITH APPLICABLE SANITARY, SAFETY
AND PLUMBING CODES.
Before connecting the steamer to water, the water
supply should be analyzed to make sure hardness is
less than 2.0 grains per gallon and pH of 7.5.  The water
supply should be clear with no sediment or suspended
material present.  If the water supply fails to meet these
standards, it will be necessary to install a water
conditioner on the boiler water feed.  APPLIANCE
FAILURE CAUSED BY INADEQUATE WATER
QUALITY IS NOT COVERED UNDER WARRANTY.
The use of strainers or filters will not remove minerals
from the water.
Cold Water
Used as boiler fill water and cold water condenser on
boiler blowdown line.  Connect a cold water line to the
1
4
” N.P.T. cold water condensor line. Twenty (20) psig
minimum water pressure is required at the connections.
VENT HOOD
Information on the construction and installation of
ventilating hoods may be obtained from the standard
for “Vapor Removal from Cooking Equipment,” NFPA
No. 96 (latest edition).