This steam cooker was inspected before leaving the
factory.  The transportation company assumes full
responsibility for safe delivery upon acceptance of the
shipment. Immediately after unpacking, check for
possible shipping damage.  If the cooker is found to be
damaged after unpacking, save the packaging material
and contact the carrier within 15 days of delivery.
Before installing, verify that the gas (natural or propane)
and/or electrical supplies agree with the specifications
on the rating plate which is located on the inside base
cabinet door.  If the supply and equipment requirements
do not agree, do not proceed with the installation.
Contact your dealer or Vulcan-Hart immediately.
LOCATION
Position the steamer in its final location.  Check that
there are sufficient clearances to service the controls,
 for door swings, etc., so there will be no problem in
making the required supply and drain connections.
Recommended clearances are 18" on the sides and
back and 36" in the front.
Allow enough space between any other piece of
equipment or a wall for access.  All service on the
compartment controls begins by removing the panel on
the right side of the compartments.  Service on the
cabinet base may require the removal of the panel on
either or both the left or right sides.
A floor drain (open gap) is required immediately below
the steamer drain.
An exhaust system should be located directly above
the steamer to exhaust steam and heat generated by
the steamer.
For Gas Powered Steam Generators Only
The equipment area must be kept free and clear of
combustible substances.
The steamer, when installed, must have a minimum
clearance from combustible and noncombustible
construction of 6" at the sides and 6" at the back.  It
must be installed on a noncombustible floor.  The
installation location must allow adequate clearances
for servicing and proper operation.
The steamer must be installed so that the flow of
combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion
chamber of the gas cabinet base generator must be
provided.  The floor area beneath the burners must be
kept free and clear.  Make sure there is an adequate
supply of air in the room to allow for combustion of the
gas at the burners.
When steamers are mounted on casters, you must use
a connector that complies with the Standard for
Connectors of Movable Gas Appliances, ANSI-Z21.69
(latest edition), and a quick-disconnect device that
complies with the Standard for Quick-Disconnect
Devices for Use With Gas Fuel, ANSI-Z21.41 (latest
edition).
Provide a gas line strain relief to limit movement of the
steamer without depending on the connector and/or any
quick-disconnect device or its associated piping to limit
movement of the steamer. Attach the gas line strain
relief to the rear of the steamer (Fig. 1).
Should it be necessary to disconnect the restraint, turn
off the gas supply before disconnection.  Reconnect the
restraint before turning the gas supply on and returning
the steamer to its installation position.
INSTALLATION CODES AND STANDARDS
Your Vulcan steamer must be installed in accordance
with:
1/2 IN. DIA. HOLE
PROVIDED FOR
STRAIN RELIEF
PL-51218