SERVICE CONNECTIONS
DIRECT STEAM, VSX24D
FIG. 2
LEGEND
A.
COLD SUPPLY WATER CONNECTION:  
1
4
” TUBING FOR COLD WATER
CONDENSER SUPPLY, AND BOILER FEED.
B.
STEAM SUPPLY CONNECTION: 
3
4
” NPT FOR STEAM COOKING (A STEAM
PRESSURE REDUCING VALVE IS MOUNTED AS STANDARD AND SET FOR 10
PSI MAXIMUM INPUT TO UNIT).
C.
ELECTRICAL CONNECTION FOR CONTROLS:  120V/60HZ/1PH/300 WATT
MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED.  (FOR
OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF
THIS CONNECTION.)
D.
DRAIN:  COPPER TUBE COMPARTMENT & EXHAUST GROUP APPROXIMATELY
2" IN DIAMETER.  (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY
UNDER THE UNIT FRAME.  DO NOT CONNECT SOLIDLY TO ANY DRAIN
CONNECTION.)
NOTE:  DIMENSIONS WHICH LOCATE THE ABOVE CONNECTIONS HAVE A
TOLERANCE OF 
±
 3 IN. (
±
 75 MM).  NORMAL DIMENSIONS ARE IN INCHES.
DIMENSIONS IN ( ) ARE IN MILLIMETERS.
EQUIPMENT CLEARANCES
TO COMBUSTIBLE CONSTRUCTION
REAR:  2 IN. MIN. (50 MM.)