Vulcan Materials vsx42rt ml-52835 ユーザーズマニュアル

ページ / 72
12
SERVICE CONNECTIONS
REGENERATING STEAM, VSX36R
FIG. 5
LEGEND
A.
STEAM SUPPLY CONNECTION:  
3
4
” NPT FOR STEAM INLET TO BOILER.  (A
STEAM PRESSURE REDUCING VALVE IS SHIPPED WITH THE UNIT AND
MUST BE FIELD INSTALLED AND ADJUSTED FOR 15 PSI MAXIMUM TO THE
UNIT.)
B.
ELECTRICAL CONNECTION FOR CONTROLS:  120V/60HZ/1PH/300 WATT
MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED.  (FOR
OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF
THIS CONNECTION.)
C.
DRAIN:  COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY
2" IN DIAMETER.  (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY
UNDER UNIT FRAME.  DO NOT CONNECT SOLIDLY TO ANY DRAIN
CONNECTION.)
D.
COLD SUPPLY WATER CONNECTION:  
1
4
” NPT FOR BOILER DRAIN &
COMPARTMENT DRAIN COLD WATER CONDENSERS, AND BOILER FEED.
NOTE:  DIMENSIONS WHICH LOCATE THE ABOVE CONNECTIONS HAVE A
TOLERANCE OF 
±
 3" (
±
75MM).  NORMAL DIMENSIONS ARE IN INCHES.  DIMENSIONS
IN ( ) ARE IN MILLIMETERS.
EQUIPMENT CLEARANCES
TO COMBUSTIBLE CONSTRUCTION
REAR:  2 IN. MIN. (50 MM.)