lift-master 65 3012 1 ユーザーズマニュアル

ページ / 1
APPLICATION:
A self-regulating immersion heater, inserted into the drain opening of the gear reducer, which keeps gear oil
warm to prevent sluggish operation or overloading in cold weather.
PACKING LIST:
Self-Regulating Heater Modification
Used on Model “GH” Operators
65-30121 
OR
65-30122
DESCRIPTION
Heater Plug
Transformer, 230V 50 VA
Immersion Heater
QUANTITY
1
1
1
PART NUMBER
11-12191
21-3260
27-12192 
SELF-REGULATING HEATER INSTALLATION 
1)
If the operator is already installed it will be
necessary to take it down or the oil will run out and it
will be difficult to refill.
2)
Tilt the operator so that the hand-chain
housing is up and remove the drain plug adjacent to
the hand-chain housing (opposite the motor) from the
gear reducer. If any oil is lost replace it with an equal
amount of Mobil 1 or equivalent.
3)
Insert the heater plug into the oil drain hole
but do not tighten it at this time.
4)
Insert the immersion heater into the heater
plug as far as it will go. Tighten the heater plug. The
plug will close around the heater and hold it in place.
5)
a) On 120 Volt Operators connect the two
heater wires to terminals L1 and L2.
b)  If the operator is not 120 Volts connect
the two heater wires to the black and white (primary)
wires on the 50VA transformer included with the kit.
(Wire nut all other transformer wires)
6)
Be sure to route the heater wires away from
moving parts and the chain hoist mechanism.
Remember these wires carry 120 Volts.
© 1998, The Chamberlain Group, Inc.
01-13390A
All Rights Reserved
WARNING
CAUTION
WARNING
WARNING
DISCONNECT POWER AT THE FUSE BOX BEFORE
PROCEEDING.
GEAR REDUCER
HEATER PLUG
IMMERSION HEATER
TRANSFORMER
(230-460 Volt Kit Only)