lift-master 658201 ユーザーズマニュアル

ページ / 1
INTERIOR AND EXTERIOR
Pneumatic Safety Edge Kits
658201 and 658202
© 2006, The Chamberlain Group, Inc.
01-658201C
All Rights Reserved
Section A-A
Door
Astragal
Retainer
Gum Air Hose
Astragal
NOTE: Astragal & Retainer
Provided by Door Supplier
Coil Cord or 
Take-up Reel
Cord Grip Fitting
(By Others)
Air Switch
(Exterior Switch
Shown)
Fit Short Piece of 
Black Signal Hose 
Inside Gum Hose
A
A
Notch Astragal for
Air Hose as Required
Gum Air Hose
(Brown Rubber)
Seal Plug
Astragal
Conduit Box Mounted
to Side at 1/2 Door Height.
1/2 Door Height
Coil
Cord
White (C)
Green (NO)
To Sensing Device 
Terminal Block. 
Refer to Wiring 
Diagram Provided 
with Operator.
EXTERIOR SWITCH P/N 501012
Red (N.O.)
Red (C)
Red (NO)
INTERIOR SWITCH P/N 50100
To Sensing Device 
Terminal Block. 
Refer to Wiring 
Diagram Provided 
with Operator.
To Adjust Switch Sensitivity;
1.  Disconnect Power to Operator.
2.  Turn the Screw Clockwise Until Contact is Made, 
 
Then Back Screw Out 1/8 of a Turn.
IMPORTANT NOTE: Brown gum air hose deteriorates in light, it
MUST be completely contained within astragal. Only black
signal hose can be in light.