WIRING
This Operator has
Control Wiring.
SUPPLEMENTAL WIRING DIAGRAM(S)
REPLACEMENT WIRING DIAGRAM
Note: Supplemental Wiring Diagrams are
to be used in addition to 1753 or 1754.
Replacement Wiring Diagram is to be used
in place of 1753 or 1754.
SPECIAL CONTROL
WIRING DATA
Wiring
Type
W A R N I N G
TO PREVENT ENTRAPMENT
DO NOT START DOOR  DOWNWARD
UNLESS DOORWAY IS CLEAR
OPEN
OPEN
C O
L
E
SE
S
O
L
C
STOP
Control Station
WARNING Notice
Push
Buttons
8
CONTROL WIRING
LOCATING THE CONTROL STATION
All operators are supplied with some type of control station. Generally a three button station
(OPEN/CLOSE/STOP) is provided. A two-position key switch or control station (OPEN/CLOSE) may be added or
substituted when requested at the time of  order. Mount the control station near the door.
IMPORTANT: Mount WARNING NOTICE beside or
below the push button station.
MOUNT WARNING NOTICE
Standard C2 or B2 Wiring
Standard operators are shipped from the factory with
jumper set for C2 wiring, which requires constant
pressure on button to close the door.  If momentary
contact on close direction is desired (B2 wiring) you
must include an entrapment protection device.  See
close control settings to the right.
Constant pressure on close (C2 wiring)
In the electrical enclosure, a RED wire was placed on
terminal block #12.   With this setting, the operator will
require constant pressure on close control in order to
keep door moving in the close direction.
Wiring Diagram label on inside cover
of electrical box
SPECIAL CONTROL WIRING
If your operator was shipped from the factory with 
non-standard control wiring or with optional
accessories that require addition instructions, refer to
the wiring diagram(s) indicated in the special control
wiring data box.  When a replacement wiring diagram
is present, wiring diagrams in this manual will not
apply.  Refer only to the replacement wiring diagram
for all connections.
To prevent possible SERIOUS INJURY or DEATH, install
reversing sensors when the 3-button control station is out of
sight of the door or ANY other control (automatic or manual) is
used. Reversing devices are recommended for ALL
installations.
WARNING
CAUTION
WARNING
WARNING
DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring. 
Momentary contact on close (B2 wiring)
Move RED wire from terminal block #12 to terminal #2.
The operator will require only momentary contact to
close the door.