UPS ECO  0.50 – 0.70 – 0.90 – 1.1 – 1.3 
 
4.2
  Rear Side 
 
 
Figure 2 – Rear Side 
 
On ECO rear side there are (see figure 2):  
 
1.
  Grounded AC Input power socket: IEC C14 type; to connect the UPS to the AC utility line.  
2.
  Input fuse: electrical specification: max current 5 A, voltage 250 V. 
3.
  Grounded UPS Output receptacles: IEC C13 type. 
 
 
5
 
Electrical Installation and First Start Up 
We advise you to follow the steps below explained for greater safety: 
1.
  Switch off all the devices (Personal Computer or other electronic devices) that need to be supplied by the 
UPS. 
2.
  Connect  the  UPS  Input  socket  to  the  AC  line  outlet  through  the  Personal  Computer  supplying  cable.  It  is 
mandatory to ground the AC line outlet according to the Safety Standards. Carefully check the grounding, 
make sure that the utility power is available, and that its range falls within the UPS specifications (refer to 
the “Technical Characteristics” chapter). 
3.
  Press the ON/OFF button on the front panel for about 2 seconds until the UPS emits a brief acoustic signal. 
The  UPS  turns  on  the  leds  the  front  panel  and  performs  a 
functioning  SELF-TEST.  After  some  seconds  the 
UPS starts to work in 
Normal mode: the LINE/BATTERY led is on. Leave the UPS in Normal mode for at least 
4 hours in order to completely recharge the batteries