Robust DataComm rdc485ic-sp Converter 仕様ガイド

ページ / 1
Model: Rdc485ic-sp
Self-Powered RS-232 to 2-wire RS-485 Converter
The rdc485ic-sp provides excellent
versatility in a compact package.
Requiring no AC power or batteries
for operation, the converter supports
asynchronous RS-232 data rate to
115200 bps over one unconditioned
twisted pair in half duplex mode.
The unit is equipped with female
DB9 connector for RS-232 and male
DB9 connector for RS-485. You can
choose either a terminal block or an
RJ-45 socket adapter for the twisted 
pair connection.
5
2
3
TXD
GND
RXD
D+
GND
D-
9
-p
in
 M
a
le
 R
S
-4
8
5
3
2
5
9
-p
in
 F
e
m
a
le
 D
E
 R
S
-2
3
2
7
8
RS
-4
85
 co
nv
er
sio
n
RS
-2
32
 co
nv
er
sio
n
Te
rm
in
at
or
 12
0R
Te
rm
in
at
o
r
Se
le
ct
io
n
Specifications
Transmission Mode:
Signal Type:
Data Rate:
Power Requirement:
Character Setting:
Asynchronous, half 
duplex point-to-point
2-wire
RS-232/RS-485
Up to 115200bps
Transparent, no
config required
Port-powered
from RS-232
Dimensions:
63L x 33W x 17H (mm)
Mechanical/Environment
Operating Range:
Storage Range:
Relative Humidity:
10 to 90% RH,
non-condensing
Comm Ports:
9-pin, male/female,
gold pins rateed 500 cycles
Case Material:
polymide, fungus/termite
resistant self-extinguishing
Weight:
approx 20g
Dimensions in mm (and inches)
Making Industrial Data Flow
Like Water ... Safely, Silently
& Sanely
www.robustdc.com
3.0(
0.12)
63.0(2.48)
53.0(2.09)
35.3(1.39)
20.0(0.79)
33.0(1.30)
17.0(0.67)
4.0(0.16)
www
.robu
stdc.c
om
Copyright © 2003 Robust DataComm, Pte Ltd
Installation
Distance:
up to 4000 feet (1200m)
on CAT 5 solid cable
The RS-232 interface is factory
configured as DCE. It connects directly
to DTE such as a terminal or PC. If you 
must use a cable to connect the DCE to
your DTE device, use a straight through
cable no longer than 50 feet (15.2m) 
For your convenience, the converter
comes with a female DB9 connector on
the RS-232 side.
Connection to the RS-232 Interface
Connection to the RS-485 Interface
To function properly, the converter
must have one twisted pair of metallic
wire. This pair must be unconditioned
metallic wire, solid conductor, unshielded
twisted pair, between 19 and 26 AWG
(the higher numbered gauges may limit
distance somewhat). We recommend
using CAT 5 solid 24AWG cable.
For your convenience, the converter
comes with DB9 male connector
(factory default configuration), RJ-45 and
terminal block (using extension adapter)
on the RS-485 side.
(Version 1.0) Specifications subject to change without notice.
Note: For communicate properly at
the RS-485 side, we strongly recommend
to connect the ground together as the
signal loop.
DB9 Male Connector configuration
1
2
3
4
5
6
7
8
9
no connection
A/A'
B/B'
Gnd
no connection
no connection
internal terminator
selection
no connection
  Note: Short Pin7 & Pin8, active the internal
terminator (120 Ohm)
1
2
3
Terminal Block configuration
A/A' (T-)
B/B' (T+)
Gnd
  Note: Jumper 1 is for the internal terminator
(120 Ohm) selection. 
RJ-45 Socket configuration
1
2
3
4
5
6
7
8
no connection
B/B'
A/A'
Gnd
no connection
no connection
Gnd
no connection
  Note: Jumper 1 is for the internal terminator
(120 Ohm) selection. 
www
.robu
stdc.c
om
Copyright © 2003 Robust DataComm, Pte Ltd
(Version 1.0) Specifications subject to change without notice.
0C to 65C 
(Ambient Temperature)
-40C to +100C
Co. & GST Reg. No: 19-9600 372-Z
Making Industrial Data Flow Like Water ... Safely, Silently, & Sanely
Robust DataComm Pte Ltd (USA) 26471 Portola Pkwy #1E-242, Foothill Ranch CA 92610-1743, +1,972-248-7466
(International) 18 Kaki Bukit Road 3 #02-08 Entrepreneur Business Centre Singapore 415978, +65,6487-5624