Hirschmann SPIDER II Giga 5T EEC PRO Rail Switch 仕様ガイド

ページ / 2
 
Hirschmann Automation and Control GmbH  
www.beldensolutions.com
 
05-08-2014
Page 1 of 2
 
Product information
SPIDER II Giga 5T EEC Pro
Industrial Ethernet:Unmanaged Industrial Ethernet Switches:SPIDER-Switches:SPIDER II Giga 5T EEC Pro
Name
SPIDER II Giga 5T EEC Pro
 
Entry Level Industrial Ethernet Rail-Switch, 10/100/1000 Mbit/s Ethernet, QoS according to IEEE 802.1D
Delivery informations
Availability
available
Product description
Description
Entry Level Industrial Ethernet Rail-Switch, 10/100/1000 Mbit/s Ethernet, QoS according to IEEE 802.1D
Port type and quantity
5 x 10/100/1000BASE-T, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
Type
SPIDER II Giga 5T EEC Pro
Order No.
943 962-102
More Interfaces
Power supply/signaling contact
1 plug-in terminal block, 3-pin / no signaling contact
Network size - length of cable
Twisted pair (TP)
0 - 100 m
Network size - cascadibility
Line - / star topology
Any
Power requirements
Operating voltage
DC 9.6 V - 32 V
Current consumption at 24 V DC
max. 150 mA
Power consumption
max. 3.6 W; 12.1 Btu(IT)/h
Service
Diagnostics
LEDs (power, link status, data, data rate)
Redundancy
Redundancy functions
n.v.
Ambient conditions
Operating temperature
-40 ºC to +70 ºC
Storage/transport temperature
-40 ºC to +85 ºC
Relative humidity (non-condensing)
10% to 95%
MTBF
1,084,142 hrs (Telcordia SR-332)
Mechanical construction
Dimensions (W x H x D)
35 mm x 138 mm x 121 mm
Mounting
DIN Rail 35 mm
Weight
240 g
Protection class
IP 30
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 4 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line
EN 61000-4-6 conducted immunity
10 V (150 kHz - 80 kHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC CFR47 Part 15 Class A
EN 55022
EN 55022 Class A