M-SFP-TX/RJ45 - M-SFP-TX/RJ45
Industrial Ethernet:System Accessories:Fiberoptic Transceiver:SFP Gigabit-Ethernet Transceiver for media module:M-SFP-TX/RJ45
Name
M-SFP-TX/RJ45
 
SFP TX Gigabit Ethernet Transceiver for Gigabit Ethernet slots, 1000 Mbit/s full duplex auto neg. fixed, cable crossing not supported
Delivery informations
Availability
available
Product description
Description
SFP TX Gigabit Ethernet Transceiver for Gigabit Ethernet slots, 1000 Mbit/s full duplex auto neg. fixed, cable crossing not supported
Port type and quantity
1 x 1000BASE-T with RJ45-socket
Type
M-SFP-TX/RJ45
Order No.
943 977-001
Network size - length of cable
Twisted pair (TP)
0 m ... 100 m
Multimode fiber (MM) 50/125 µm
n/a
Multimode fiber (MM) 62.5/125 µm
n/a
Single mode fiber (SM) 9/125 µm
n/a
Single mode fiber (LH) 9/125 µm (long haul
transceiver)
n/a
Power requirements
Operating voltage
power supply via the switch
Power consumption
1 W
Service
Diagnostics
n/a
Ambient conditions
Operating temperature
0 ºC up to +60 ºC
Storage/transport temperature
-40°C up to +85°C
Relative humidity (non-condensing)
10% up to 95%
MTBF
45 years, Telcordia GR-468-CORE
Mechanical construction
Dimensions (W x H x D)
14 mm x 14 mm x 70 mm
Mounting
SFP slot
Weight
40 g
Protection class
IP 20
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
EN 61000-4-6 conducted immunity
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC CFR47 Part 15 Class A
EN 55022
EN 55022 Class A
Approvals
Safety of industrial control equipment
cUL 60950-1
Hazardous locations
n/a