Panduit IAEBHC6 CAT 6 Bulkhead Coupler 仕様ガイド
T e s t R e s u l t s
©2015 Panduit Corp.
ALL RIGHS RESERVED.
COSP255--WW-ENG
3/2015
1.487
(37.77)
5.336
(135.54)
1.305
(33.16)
1.487
(37.77)
5.336
(135.54)
IAEBH6
Dimensions are in inches (Dimensions in parentheses are metric)
IndustrialNet
™
TX6
™
PLUS Connectors
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
Phone: 52.33.3777.6000
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
Visit us at www.panduit.com
For more information
IAEBHC6
Mechanical Test
Test Method
Measurement
Required Performance
Normal Force
—
Load (grams)
> 100
Vibration
IEC 512-6d
Circuit Resistance Change (mOhms)
< 40
Shock
IEC 512-6c
Contact Disturbance (microsecond)
< 5
Durability
IEC 512-9a
Circuit Resistance Change (mOhms)
< 40
Mating/Unmating
IEC 512-13b
Mating Force (N)
< 20
Unmating Force (N)
< 20
Mechanical Test
Test Method
Measurement
Required Performance
Low Level Circuit Resistance
IEC 512-2a
Resistance (mOhms)
< 20
Dielectric Withstand Voltage
IEC 512-4a
1000VAC, 1 minute
Passed
Insulation Resistance
IEC 512-3a
Resistance (MOhms)
> 500
Mechanical Test
Test Method
Measurement
Required Performance
Temperature Life
IEC 512-9b
Circuit Resistance Change (mOhms)
< 40
Humidity
IEC 512-11c
Circuit Resistance Change (mOhms)
< 40
Thermal Shock
IEC 512-11d
Circuit Resistance Change (mOhms)
< 40
Climactic Sequence
IEC 512-11a
Circuit Resistance Change (mOhms)
< 40
Flowing Mixed Gas Corrosion
IEC 512-11g
Circuit Resistance Change (mOhms)
< 40