Panduit IAEBHC6 CAT 6 Bulkhead Coupler 仕様ガイド

ページ / 2
T e s t   R e s u l t s
©2015 Panduit Corp. 
ALL RIGHS RESERVED.
COSP255--WW-ENG
3/2015
1.487
(37.77)
5.336
(135.54)
1.305
(33.16)
1.487
(37.77)
5.336
(135.54)
IAEBH6
Dimensions are in inches (Dimensions in parentheses are metric)
IndustrialNet
 TX6
 PLUS Connectors
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
Phone: 52.33.3777.6000
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
Visit us at www.panduit.com
For more information
IAEBHC6
Mechanical Test
Test Method
Measurement
Required Performance
Normal Force
Load (grams)
> 100
Vibration
IEC 512-6d
Circuit Resistance Change (mOhms)
< 40
Shock
IEC 512-6c
Contact Disturbance (microsecond)
< 5
Durability
IEC 512-9a
Circuit Resistance Change (mOhms)
< 40
Mating/Unmating
IEC 512-13b
Mating Force (N)
< 20
Unmating Force (N)
< 20
Mechanical Test
Test Method
Measurement
Required Performance
Low Level Circuit Resistance
IEC 512-2a
Resistance (mOhms)
< 20
Dielectric Withstand Voltage
IEC 512-4a
1000VAC, 1 minute
Passed
Insulation Resistance
IEC 512-3a
Resistance (MOhms)
> 500
Mechanical Test
Test Method
Measurement
Required Performance
Temperature Life
IEC 512-9b
Circuit Resistance Change (mOhms)
< 40
Humidity
IEC 512-11c
Circuit Resistance Change (mOhms)
< 40
Thermal Shock
IEC 512-11d
Circuit Resistance Change (mOhms)
< 40
Climactic Sequence
IEC 512-11a
Circuit Resistance Change (mOhms)
< 40
Flowing Mixed Gas Corrosion
IEC 512-11g
Circuit Resistance Change (mOhms)
< 40