Hirschmann RS20-2400M2M2SDAU Switch 仕様ガイド

ページ / 2
 
Hirschmann Automation and Control GmbH  
www.beldensolutions.com
 
06-04-2015
Page 1 of 2
 
Product information
Compact OpenRail unmanaged Fast Ethernet switch -
RS20-2400M2M2SDAUHH
Industrial Ethernet:Unmanaged Industrial Ethernet Switches:Configurable Unmanaged Switches:Fast Ethernet switches:Compact OpenRail unmanaged Fast Ethernet switch
Name
Compact OpenRail unmanaged Fast Ethernet switch
 
24 port Fast-Ethernet-Switch, unmanaged, for DIN rail store-and-forward-switching, fanless design
Delivery informations
Availability
available
Product description
Description
24 port Fast-Ethernet-Switch, unmanaged, for DIN rail store-and-forward-switching, fanless design
Port type and quantity
24 ports in total; 1. uplink: 100BASE-FX, MM-SC; 2. uplink: 100BASE-FX, MM-SC; 22 x standard 10/100 BASE TX, RJ45
Type
RS20-2400M2M2SDAUHH
Order No.
RS20-2400M2M2SDAUHH
More Interfaces
Power supply/signaling contact
1 x plug-in terminal block, 6-pin
Network size - length of cable
Multimode fiber (MM) 50/125 µm
0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 d/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm
0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Network size - cascadibility
Line - / star topology
Any
Power requirements
Operating voltage
12/24/48 V DC (9,6-60) V and 24 V AC (18-30) V (redundant)
Current consumption at 24 V DC
663
Current consumption at 48 V DC
332
Power output in Btu (IT) h
54.3
Ambient conditions
Operating temperature
0 ºC ... 60 ºC
Storage/transport temperature
-40 ºC ... 70 ºC
Relative humidity (non-condensing)
10 % ... 95 %
MTBF
33.8 years (MIL-HDBK-217F)
Protective paint on PCB
No
Mechanical construction
Dimensions (W x H x D)
110 mm x 131 mm x 111 mm
Mounting
DIN Rail
Weight
650 g
Protection class
IP20
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 schocks
IEC 60068-2-6 vibration
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13,2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
power line: 2kV (line/earth), 1kV (line/line), 1kV data line
EN 61000-4-6 conducted immunity
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC CFR47 Part 15
EN 55022
EN 55022 Class A