Hirschmann MB-2T MICE Expansion Backplane Module 仕様ガイド

ページ / 2
 
Hirschmann Automation and Control GmbH  
www.beldensolutions.com
 
08-08-2014
Page 1 of 2
 
Product information
MB-2T
Industrial Ethernet:Modular Industrial Switches:Modular switches:Accessories:MB-2T
Name
MB-2T
 
Expansion backplane with 2 slots for MS20/30-16 and MS4128 MICE switches
Delivery informations
Availability
available
Product description
Description
Expansion backplane with 2 slots for
MS20/30-16 and MS4128 MICE switches
Port type and quantity
2 slots integrated on backplane
(8 ports possible via media modules)
Type
MB-2T
Order No.
943 733-102
Power requirements
Power consumption
0 W
Ambient conditions
Operating temperature
0 ºC bis +60 ºC standart ( optional -40ºC to +70ºC)
Storage/transport temperature
-25 ºC to +70 ºC
Relative humidity (non-condensing)
10% to 95%
MTBF
1146.1 years; MIL-HDBK 217F: Gb 25 ºC
Mechanical construction
Dimensions (W x H x D)
79 mm x 134 mm x 22 mm
Mounting
DIN Rail 35 mm
Weight
150 g
Protection class
IP 20
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
Power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC CFR47 Part 15 Class A
EN 55022
EN 55022 Class A
Approvals
Safety of industrial control equipment
cUL 508
Hazardous locations
ISA 12.12.01 Class 1 Div. 2 (pending)
Shipbuilding
Germanischer Lloyd, ABS, BV, DNV, LR, KR, RINA
Railway norm
EN50121-4