Hirschmann MM4-2TX/SFP MICE Media Module 仕様ガイド

ページ / 2
 
Hirschmann Automation and Control GmbH  
www.beldensolutions.com
 
02-04-2015
Page 1 of 2
 
Product information
MM4-2TX/SFP
Industrial Ethernet:Modular Industrial Switches:Media modules:Gigabit Ethernet MICE media modules:MM4-2TX/SFP
Name
MM4-2TX/SFP
 
Media module for MICE Switch MS4128, MS30xx,10/100/1000BASE-TX und 1000BASE-SX/LX
Delivery informations
Availability
available
Product description
Description
Media module for MICE Switch MS4128, MS30xx,
10/100/1000BASE-TX und 1000BASE-SX/LX
Port type and quantity
2 x 1000BASE-fiber with SFP modules, or
2 x 10/100/1000BASE-TX, TP cable, RJ45-sockets, autocrossing, autoneg., autopolarity
any combination TX or SFP, 1 SFP deactivates 1TX, up to 2 ports
Type
MM4-2TX/SFP
Order No.
943 622-001
Network size - length of cable
Twisted pair (TP)
0 - 100 m
Multimode fiber (MM) 50/125 µm
cf. SFP module M-SFP-SX/LC and M-SFP-LX/LC
Multimode fiber (MM) 62.5/125 µm
cf. SFP module M-SFP-SX/LC and M-SFP-LX/LC
Single mode fiber (SM) 9/125 µm
cf. SFP module M-SFP-LX/LC
Single mode fiber (LH) 9/125 µm (long haul
transceiver)
cf. SFP FO module M-SFP-LH/LC and M-SFP-LH+/LC
Power requirements
Operating voltage
power supply via the backplane of the MICE switch
Power consumption
2 W
Service
Diagnostics
LEDs (power, link status, data, 1000 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature
0 ºC bis +60 ºC standart ( optional -40ºC to +70ºC)
Storage/transport temperature
-40 ºC to +70 ºC
Protective paint on PCB
optional
Relative humidity (non-condensing)
10% to 95%
MTBF
163 years; MIL-HDBK 217F: Gb 25 ºC
Mechanical construction
Dimensions (W x H x D)
38 mm x 134 mm x 77 mm
Mounting
Backplane
Weight
160 g
Protection class
IP 20
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
EN 61000-4-6 conducted immunity
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)