Hirschmann SPIDER-PL-20-08T1999999TX9HHHH Rail Switch 仕様ガイド

ページ / 2
 
Hirschmann Automation and Control GmbH  
www.beldensolutions.com
 
17-11-2016
Page 1 of 2
 
Product information
SPIDER III - SPIDER-PL-20-08T1999999TX9HHHH
Industrial Ethernet:Unmanaged Industrial Ethernet Switches:SPIDER III-Switches:SPIDER III
Name
SPIDER III
 
Unmanaged, Industrial ETHERNET Rail Switch, fanless design, store and forward switching mode, 10/100 Mbit/s Ethernet
Delivery informations
Availability
available
Product description
Description
Unmanaged, Industrial ETHERNET Rail Switch, fanless design, store and forward switching mode, 10/100 Mbit/s Ethernet
Port type and quantity
8x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
Type
SPIDER-PL-20-08T1999999TX9HHHH
Order No.
942141117
More Interfaces
Power supply/signaling contact
1 x plug-in terminal block, 6-pin
USB interface
1 x USB for configuration
Network size - length of cable
Twisted pair (TP)
0 m ... 100 m
Network size - cascadibility
Line - / star topology
any
Power requirements
Operating voltage
12/24 V DC (9.6 - 32 V DC), redundant
Current consumption at 24 V DC
Max. 100 mA
Power consumption
Max. 2.6 W, 8.8 Btu (IT) h
Ambient conditions
Operating temperature
-40 ºC ... 70 ºC
Storage/transport temperature
-40 ºC ... 85 ºC
Relative humidity (non-condensing)
0 % ... 95 %
MTBF (Telcordia)
1.206.410 hours; Telcordia SR-332; Gb 25°C
Mechanical construction
Dimensions (W x H x D)
49 x 135 x 117 mm (w/o terminal block)
Mounting
DIN Rail
Weight
440 g
Protection class
IP40 (metal housing)
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min; 1 g, 8.4–150 Hz, 10 cycles, 1 octave/min
Configurable parameters
Configurable parameters
Global settings: power supply unit alarm, aging time, QoS 802.1p mapping, QoS DSCP mapping; Port settings: flow control, port admin state, broadcast storm
protection/threshold, multicast storm protection/threshold, QoS Trust Mode, port based priority, link alarm; TX port settings: auto-negotiation, speed, duplex
mode, auto-crossing, MDI state, energy efficient ethernet; FX port settings: duplex mode
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 4 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity
10 V (150 kHz-80 MHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC 47 CFR Part 15 Class A
EN 55022
EN 55022 Class A