Hirschmann MM3-2FXS2/2TX1-EEC MICE Media Module 仕様ガイド

ページ / 2
 
Hirschmann Automation and Control GmbH  
www.beldensolutions.com
 
02-04-2015
Page 1 of 2
 
Product information
MM3-2FXS2/2TX1-EEC
Industrial Ethernet:Modular Industrial Switches:Media modules:Ethernet / Fast-Ethernet MICE Media Modules:MM3-2FXS2/2TX1-EEC
Name
MM3-2FXS2/2TX1-EEC
 
Media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX single mode F/O
Delivery informations
Availability
available
Product description
Description
Media module for MICE Switches (MS...),
100BASE-TX and 100BASE-FX single mode F/O
Port type and quantity
2 x 100BASE-FX, SM cables, SC sockets
2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
Type
MM3-2FXS2/2TX1-EEC
Order No.
943 762-151
Network size - length of cable
Twisted pair (TP)
0 -100 m
Single mode fiber (SM) 9/125 µm
0 -32.5 km
16 dB link budget at 1300 nm
A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Power requirements
Operating voltage
power supply via the backplane of the MICE switch
Power consumption
3,4 W
Service
Diagnostics
LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature
-40 ºC to +70 ºC
Storage/transport temperature
-40 ºC to +70 ºC
Protective paint on PCB
optional
Relative humidity (non-condensing)
10% to 95%
MTBF
64.9 years; MIL-HDBK 217F: Gb 25 ºC
Mechanical construction
Dimensions (W x H x D)
38 mm x 134 mm x 118 mm
Mounting
Backplane
Weight
180 g
Protection class
IP 20
Mechanical stability
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
EN 61000-4-6 conducted immunity
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15
FCC CFR47 Part 15 Class A
EN 55022
EN 55022 Class A