Puls ML60.121 Power Supply 仕様ガイド

ページ / 23
 
 
ML60.121
 
 
MiniLine-2 
 
12V,
 
4.5A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
 
 
P
OWER 
S
UPPLY
 
ƒ  100-240V Wide Range Input 
ƒ  NEC Class 2 Compliant 
ƒ  Adjustable Output Voltage 
ƒ  Efficiency up to 87.2% 
ƒ  Low No-load Losses and Excellent Partial-load Efficiency 
ƒ  Compact Design, Width only 45mm 
ƒ  Full Power between -10°C and +60°C 
ƒ  Large International Approval Package 
ƒ  3 Year Warranty 
 
 
 
 
1/23
G
ENERAL 
D
ESCRIPTION
 
A compact size, light weight, simple mounting onto the 
DIN-rail and the utilization of only quality components 
are what makes the MiniLine power supplies so easy to 
use and install within seconds. 
A rugged electrical and mechanical design as well as a 
high immunity against electrical disturbances on the 
mains provides reliable output power. This offers 
superior protection for equipment which is connected 
to the public mains network or is exposed to a critical 
industrial environment. 
The MiniLine series offers output voltages from 5 to 
56Vdc and a power rating from 15W to 120W. 
The supplementary MiniLine decoupling diode module 
MLY10.241 allows building of redundant systems or to 
protect against back-feeding voltages. 
 
S
HORT
-
FORM 
D
ATA
 
 
Output voltage 
DC 12V 
 
Adjustment range 
12 - 15V 
 
Output current 
4.5A at 12V 
3.6A at 15V 
 
Output power 
54W 
 
Output ripple 
< 50mVpp 
20Hz to 20MHz 
Input voltage 
AC 100-240V  
-15% / +10% 
AC 100V mains 
requires derating 
Mains frequency 
50-60Hz  
±6% 
AC Input current 
0.91 / 0.54A 
at 120 / 230Vac 
Power factor 
0.58 / 0.5 
at 120 / 230Vac 
AC Inrush current 
typ. 16 / 32A 
peak value at 120 
/ 230Vac 40°C 
and cold start 
DC Input 
88-375Vdc 
below 130Vdc 
derating required
Efficiency 
85.3 / 87.2% 
at 120 / 230Vac 
Losses 
9.3 / 7.9W 
at 120 / 230Vac 
Temperature range -10°C to +70°C 
operational 
Derating 
1.4W/°C 
+60 to +70°C 
Hold-up time 
typ. 25 / 113ms 
at 120 / 230Vac 
Dimensions 45x75x91mm 
WxHxD 
Weight 
250g / 0.55lb 
 
 
 
O
RDER 
N
UMBERS
 
Power Supply  ML60.121 
12-15V Standard unit 
Accessory MLY10.241 
Redundancy 
Module 
 ZM3.WALL 
Wall 
mount 
bracket 
 
M
ARKINGS
 
 
 
Ind. Cont. Eq. UL 508
 
 
UL 60950-1
 
 
Marine
 
 
Class I Div 2
 
NEC 
Class 2
 
 
EMC, LVD, RoHS
 
Mar. 2013 / Rev. 1.2  DS--ML60.121-EN 
All parameters are specified at 12V, 4.5A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 