Dbx dbx® 234xs オーナーマニュアル
![Dbx](https://files.manualsbrain.com/attachments/15d7c89940a6e680aca1f1315b69680a358b3538/common/fit/150/50/3dc074d8c456028e017b4eb27613138e79f21fcf6180b7ee58c2b61c2ee2/brand_logo.gif)
12
223s, 223xs,
234s, 234xs
234s, 234xs
MONO 3-WAY MODE
In 3-way mono operation the controls are marked in red ABOVE the horizontal black line.
Front panel controls not described in this section are not active in mono 3-way mode. LEDs
are disabled for controls which are non-functional in this mode.
In 3-way mono operation the controls are marked in red ABOVE the horizontal black line.
Front panel controls not described in this section are not active in mono 3-way mode. LEDs
are disabled for controls which are non-functional in this mode.
[1]
I
NPUT
G
AIN
Controls the input level with +/- 12 dB of gain.
[2]
L
OW
/M
ID
Selects crossover point between LOW and MID
frequencies.
[3]
[3]
L
OW
O
UTPUT
Controls the LOW frequency output level with a
range of
range of
to +6 dB.
[4]
M
ID
/H
IGH
Selects the crossover point between MID and
HIGH frequencies.
HIGH frequencies.
[5]
M
ID
O
UTPUT
Controls the MID frequency output level with a
range of
range of
to +6 dB.
[6]
H
IGH
O
UTPUT
Controls the HIGH frequency output level with a
range of
range of
to +6 dB.
[7]
L
OW
C
UT
Switch for selecting the 40 Hz high pass filter. An
LED indicates the selection.
LED indicates the selection.
[8]
X
10 LED
Indicates that the LOW/MID crossover range is
450 Hz to 9.6 kHz.
450 Hz to 9.6 kHz.
[9]
P
HASE
I
NVERT
Switch for reversing the polarity on the LOW
Output. An LED indicates that the phase is
reversed.
Output. An LED indicates that the phase is
reversed.
[10]
M
ONO
LED indicating mono mode operation.
[11]
X
10 LED
Indicates that the MID/HIGH crossover frequency
range is 450 Hz to 9.6 kHz
range is 450 Hz to 9.6 kHz
[12]
P
HASE
I
NVERT
Switch for reversing the polarity on the MID
Output. An LED indicates that the phase is
reversed.
Output. An LED indicates that the phase is
reversed.
[13]
P
HASE
I
NVERT
Switch for reversing the polarity on the High
Output. An LED indicates that the phase is
reversed.
Output. An LED indicates that the phase is
reversed.
Section 2
Operating Controls
7