9. Lens Back adjustment
[Preparations]
• Siemens star chart
• POWER switch of camera: ON
• POWER switch of camera: ON
[Adjustment conditions]
• Make a copy of A4 size siemens chart, which is attached to the service manual, in enlarged A3 size or larger.
• Illumination above the object should be 400 lux ± 10 %.
• Set the siemens star chart at 145.72 cm ± 3 cm (between Siemens star chart and the surface of camera's
• Illumination above the object should be 400 lux ± 10 %.
• Set the siemens star chart at 145.72 cm ± 3 cm (between Siemens star chart and the surface of camera's
protection lens front)
[Adjustment methods]
• Click on "LENS BACK INSPECTION AND ADJUSTMENT".
• Click on the "MATCH THE VIEW ANGLE" button, and check by the LCD monitor so that the siemens star
• Click on the "MATCH THE VIEW ANGLE" button, and check by the LCD monitor so that the siemens star
chart comes in center of the screen.
• Click on "INSPECT/ADJUST" button.
(In case of replacing the main PCB or lens-barrel unit, input the 2 figures on the seal attached to the
(In case of replacing the main PCB or lens-barrel unit, input the 2 figures on the seal attached to the
lens-barrel into "a:" and "b:" of FFD ADJUSTMENT, then click on the "WRITE" button.
カメラ
145.72cm±3cm
ジーメンス
スターチャート
Camera
Siemens star chart
145.72 cm ± 3 cm
• When the inspection result of the lens is displayed,
select and click "YES" or "NO" on the "WAS
MEASURED VALUE STANDARD?" screen.
MEASURED VALUE STANDARD?" screen.
• By clicking "NO" on the "WAS MEASURED
VALUE STANDARD?" screen, the adjustment
starts.
starts.
• Click "OK" when the adjustment is completed.
• Repeat inspections and adjustments until "YES"
• Repeat inspections and adjustments until "YES"
is clicked on the "WAS MEASURED VALUE
STANDARD?" screen.
STANDARD?" screen.
• Click the "X" close button in the upper-right corner
on the adjustment result screen.
Judgement standard: p1, p2: -6 ~ +6
"X"
a:
b:
"MATCH THE VIEW
ANGLE"
"INSPECT/ADJUST"