Nikon Coolpix SQ ユーザーガイド

ページ / 60
VAA12201-R.3581.A
                    - R1 ・ SQ -
Item
Judgmental standard
Applied tool(s)
External view
Gap/Difference in 
level (e.g. height) 
External and internal 
conditions 
• General components
Gap: 0.3mm or less
Difference in level: 0.15mm or less
• When closing the battery cover:
Gap: 0.5mm or less (Difference between right and left must 
not be noticeable.)
• Neither noticeable damages nor dirt must be found.
• No abnormal noise must be heard when pushing the main 
body.
(Visually check with fluorescent lamp or natural light.)
Visual check
Operation/
Operationality
Operation
   
Operatinality of 
buttons
Lever/Knob
Each cover/lid
Swivelling unit
 
No malfunction or abnormal sounds must be found.
 
(In operation, check the function by shaking the camera or
  press lightly the camera against the Linoleum-laid desk.
)
• 
Neither malfunction nor abnormal sounds must be found.
 
 A sense of  "clicking" on each button is clear.
 
"Clicking" must be executed at the same time or almost the 
same time as turning the switch ON.
(Check this in normal operation.)
• 
A sense of  "clicking" on lever/knob is clear.  Neither evident 
"caught-in-mechanism" nor "rubbed-in-mechanism" nor play 
must be found.
(Check this in normal operation.)
• No play must be found when closing cover/lid.
• Neither evident "caught-in-mechanism" nor "rubbed-in-mech-
anism" nor abnormal noise must be found.
(Check this by opening or closing cover/lid.)
• A sense of  "clicking" of the unit is clear.  Neither "caught-in-
mechanism", nor "rubbed-in-mechanism",  nor evident play 
must be found.
 (Check this for every angle of rotation by operating.)
Primary battery/
Secondary battery
Lens performance
Focal length
WIDE-end (Compelling 
)
5.6  mm  +5%
   
-1%
TELE-end  (Compelling ∞)
16.8 mm  +1%
   
-5%
Focal length
measuring 
instrument
Lens driving tool
INSPECTION STANDARD