Selex ES SPA F567DHDE-HP ユーザーズマニュアル
SELEX Communications
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed
by SELEX Communications S.p.A. in writing
17
July 2010
5.1.6 48 Vdc input
Use the connector marked in red to connect RBS to the output of the 48 VDC power supply. Each
level must be connected separately the 48 VDC power supply. The SRB is galvanically insulated..
Interconnecting points
Type of connector terminating
the cable
Type of cable/conductor
Power supply 35 – 75 Vdc
Polarised SUB–D 3W3 female
connector
connector
Section of each wire ≥ 4 sq.mm.
(for length < 6 m)
(for length < 6 m)
D-SUB 3W3 female pinout
PIN
A1 Negative
voltage
A2 Not
used
A3 Positive
voltage
(soldering side view)
Hereafter the power cable supplied with the 48 Vdc powered device is shown. The cable is provided