Selex ES SPA F567DHDE-HP ユーザーズマニュアル

ページ / 60
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
17
 
   July 2010 
 
 
5.1.6  48 Vdc input 
Use the connector marked in red to connect RBS to the output of the 48 VDC power supply.  Each 
level must be connected separately the 48 VDC power supply. The SRB is galvanically insulated.. 
 
Interconnecting points 
Type of connector terminating
the cable 
Type of cable/conductor 
Power supply 35 – 75 Vdc 
Polarised  SUB–D  3W3  female 
connector 
Section of each wire ≥ 4 sq.mm. 
(for length < 6 m) 
 
D-SUB 3W3 female pinout  
PIN  
A1 Negative 
voltage 
A2 Not 
used 
A3 Positive 
voltage 
 
 
 
(soldering side view) 
Hereafter the power cable supplied with the 48 Vdc powered device is shown. The cable is provided 
with D-SUB 3W3 female connector and a 30A fuse.