Selex ES SPA F567DHDE-HP ユーザーズマニュアル
SELEX Communications
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed
by SELEX Communications S.p.A. in writing
44
July 2010
6.
Configuration
The hardware configuration, where applicable, is described in the installation section of this manual.
Hardware configuration is limited only to hardware related characteristics such as electrical interfaces.
A parameter configuration must be done to adjust each device to the user need. This procedure is
described in the manual of the configuration software. Please refers to it for more information.
A list of values for each parameter for each device is provided in a separate document on demand.
Please refer to it to set the proper value for each parameter.
To connect the PC with the configuration software to the RBS follow the procedure described in the
Local Maintenance Interface section.
7.
Maintenance
7.1 Module features, alarms and troubleshooting
7.1.1 CORE module
The CORE module, for its versatility and potentiality, is the core of ECOS-D RBS. This
module is equipped with devices for numerical computation (DSP, FPGA) and control
(microprocessor).
The primary functionalities of the Core Module are:
• MMI (Man Machine Interface) to allow an operator to interact with the
device
• Main Simulcast Management, implementing the voting algorithm,
equalization and a matrix of AF signals.
• local and remote management of the device.
The CORE MMI makes available to a technical operator the following functionalities.
• Radio frequencies settings (RX e TX);
• RF transmission power settings (Hi / Low);
• Enable / disable of input/output lines (radio and wired);
• Speak and listen on selectable interfaces;
• Measures:
o
power supply (V);
o
RSSI
(dBm);
o
RF transmit power (dBm);