Selex ES SPA F567DHDE-HP ユーザーズマニュアル

ページ / 60
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
47
 
   July 2010 
 
 
 
Red 
Line 1 TX 
Line 1 on TX 
Green 
Line 2 RX  
Line 2 on RX 
 
Red 
Line 2 TX 
Line 2 on TX 
Green 
Line 3 RX  
Line 3 on RX 
 
Red 
Line 3 TX 
Line 3 on TX 
Green 
Line 4 RX  
Line 4 on RX 
 
Red 
Line 4 TX 
Line 4 on TX 
Green 
Status1  
 
Red 
DATA bus fail 
failure MTCH of DSP 
Green 
Status2  
 
Red 
Logic fail 
µP and DSP not communicate 
Green 
CTRL bus busy 
Activity on Control Bus 
 
Red 
CTRL bus fail 
failure of BUS µP 
Green 
Upload  
Ongoing download code  
 
Red 
Upload Fail 
Download code KO 
7.1.3 SWITCH module 
The Switch module realizes a "solid state" switch (MOSFET) device for the distribution of the 
power necessary for the proper working of all the modules of the ECOS-D RBS. In particular 
its primary task is to distribute the 12 Vdc nominal voltage (Master voltage) and 7 Vdc 
nominal voltage (Slave voltage). 
The 7 Vdc Slave voltage is used by all the other modules to power their logic. It is generated 
by the switch module for direct conversion from the 12 Vdc Master voltage. 
The switch module provides: 
•  ON / OFF of all the modules on the same RBS 
•  Protection against Extra Current (short circuit or overload > 22 A ± 5%) 
•  Protection against Extra voltage (maximum input voltage equal to 30 Vdc ± 5%) 
•  Protection against voltages outside the guaranteed operating range [10.8 ÷ 15.6 Vdc]. 
•  Protection against reverse polarity input voltage. 
•  Protection against over temperature inside the module itself (≥ 100 ° C ± 1%). 
The front panel is provided with bi-color leds to help in troubleshooting the system. The table below 
describes the meaning of the leds: 
LED 
Color 
Label 
Description 
Green
  
Vin OK 
Normally operating