Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
9
 
   July 2010 
 
 
Humidity  
 should not exceed 90% relative humidity @ 50°C (122°F) non 
condensating 
Air Quality 
 For equipment operating in an environmentally controlled 
environment with repeater(s) rack mounted, the airborne 
particle level must not exceed 25 μg/m³. 
For equipment operating in an area which is not 
environmentally controlled (repeater(s) cabinet mounted), air 
borne particle level must not exceed 90 μg/m³. 
Equipment Ventilation 
the repeater is equipped with two cooling fans that are used to 
provide forced convection cooling. Customer-supplied 
cabinets must be equipped with ventilation slots or openings 
in the front (for air entry) and back or side panels (for air to 
exit). If several repeaters are installed in a single cabinet, be 
sure ventilation openings surround each repeater to allow for 
adequate cooling. A minimum of ½ RU (4,4 cm – 0,8 inches) 
must be left among devices installed in the same cabinet.