Selex ES SPA F867DHDE-H ユーザーズマニュアル

ページ / 62
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
18
 
   July 2010 
 
 
6.1.4  Electrical wiring 
The electrical wiring must be done using appropriate cables thus assuring the equipment responds to 
the electromagnetic compatibility standards. 
The  cable  terminates  to  flying  connectors  which  have  to  be  connected  to  the  corresponding 
connectors on the equipment front. 
Position  and  pin–out  of  the  equipment  connectors  are  available  in  the  appropriate  section  in  the 
following of this document. 
6.1.5  Unit grounding 
The device is equipped with a ground nut located on the rear panel of the device and identified by a 
 label. This nut must be used for a direct connection of the device to the site grounding, even if the 
device is included in a cabinet. All antenna cables and DC power cabling should be properly grounded 
and lightning protected. Failure to provide proper lightning protection may result in permanent damage 
to the radio equipment. 
 
 
Figure 5 Ground connector 
Interconnecting points 
Type of connector terminating 
the cable 
Type of cable/conductor 
Ground 
M6 nut 
Section area ≥ 6 sq. mm 
 
Ground 
connector