Selex ES SPA F867DHDE-H ユーザーズマニュアル

ページ / 62
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
33
 
   July 2010 
 
 
6.4 Syncronization Interfaces 
6.4.1  Main GPS Interface 
In  order  to  connect  the  Main  GPS  antenna  to the RBS, connect the GPS antenna to the  SMA-BNC 
“Main GPS” connector shown in the following figure.  
 
 
 
Interconnecting points 
Type of connector terminating 
the cable 
Type of cable/conductor 
GPS 
SMA male connector 
50 ohm coaxial cable with 
double shield 
 
GPS Antenna