Selex ES SPA F867DHDE-H ユーザーズマニュアル

ページ / 62
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
40
 
   July 2010 
 
 
RS232 
RS232 standards are defined by EIA/TIA (Electronic Industries Alliance /Telecommunications Industry 
Association). RS232 defines both the physical and electrical characteristics of the interface. RS232 is 
an Active LOW voltage driven interface and operates at +12V to -12V. RS232 is a serial interface for 
the transmission of point to point digital data. Description of the connector’s pins is from DTE to DCE. 
The RBS acts as a DCE. 
RS232 female pinout
 
PIN 
 
Mean 
 
not used 
RX 
Data from DCE to DTE 
TX 
Data from DTE to DCE 
 
not used 
GND 
Ground 
 
not used 
RTS 
Ready To Send (from DTE) 
CTS 
Clear To Send (to DTE) 
 
not used 
 
 
RS422 
RS422 is a balanced serial interface for the transmission of point to point digital data. The advantage 
of  a  balanced  signal  is  the  greater  immunity  to  noise.  The  EIA  describes  RS422  as  a  DTE  to  DCE 
interface for point-to-point connections. Description of the connector’s pins is from DTE to DCE. The 
RBS acts as a DCE. 
RS422 female pinout 
(only on request) 
PIN 
 
Mean 
GND 
Ground 
TX + 
Data from DTE to DCE 
 
not used 
RX + 
Data from DCE to DTE 
GND 
Ground 
 
not used 
TX - 
Data from DTE to DCE 
 
not used 
RX - 
Data from DCE to DTE