8.1.3  SWITCH module 
The Switch module realizes a "solid state" switch (MOSFET) device for the distribution of the 
power necessary for the proper working of all the modules of the ECOS-D RBS. In particular 
its  primary  task  is  to  distribute  the  12  Vdc  nominal  voltage  (Master  voltage)  and  7  Vdc 
nominal voltage (Slave voltage). 
The 7 Vdc Slave voltage is used by all the other modules to power their logic. It is generated 
by the switch module for direct conversion from the 12 Vdc Master voltage. 
The switch module provides: 
• 
ON / OFF of all the modules on the same RBS 
• 
Protection against Extra Current (short circuit or overload > 22 A ± 5%) 
• 
Protection against Extra voltage (maximum input voltage equal to 30 Vdc ± 5%) 
• 
Protection against voltages outside the guaranteed operating range [10.8 ÷ 15.6 Vdc]. 
• 
Protection against reverse polarity input voltage. 
• 
Protection against over temperature inside the module itself (≥ 100 ° C ± 1%). 
The  front  panel  is  provided  with  bi-color  leds  to  help  in  troubleshooting  the  system.  The  table  below 
describes the meaning of the leds: 
LED 
Color 
Label 
Description 
Green
  
Vin OK 
Normally operating 
 
Red 
Vin fail 
Input voltage out of range 
Green
  
Vout ok 
RBS internal voltage levels are correct 
 
Red 
Vout fail 
RBS internal voltage failure 
Green
 
Control bus busy 
Activity on the control bus 
 
Red 
Control bus fail 
control bus among the modules is in failure 
 
Red 
blink 
Control bus fail 
Bad message received 
Green
 
Upload 
Firmware upload in progress 
 
Red 
Upload fail 
Firmware upload failed