z  Log Window 
The log window is used to display all the messages and data sent to and from the 
reader board. This information is also stored in the rfid-reader.log file which can 
be opened with a text editor (Notepad). 
 
The relevant information returned by the Reader (transponder response, register 
content) is always in brackets to distinguish it from other data in host-to-reader 
data exchange. 
z  Frequency selection 
Frequency selection field and four buttons on the right side of the GUI window 
allow user to select operation frequency. The two buttons on the left change 
frequency in 200 kHz. 
 
z  Control buttons 
The following buttons change operation of the Reader: 
9  AGC – Automatic Gain Control setting   
9  AGL – Automatic Gain Leveling setting 
9  Enable RF Power – turn on / off RF power 
z  COM port 
If automatic port selection fails upon GUI initialization you can select the port 
and try to execute the “Inventory Round” operation in the EPC tab. In case the 
Reader will be reset (or removes power during RF debug tab measurement) 
Reconnect button should be used to reestablish connection. 
Current Frequency 
Coarse adjustment buttons 
Fine adjustment buttons