Stratasys Ltd DUPCAB ユーザーズマニュアル
Safety
2–2
DOC08010 Rev. A (DRAFT 1)
Safety Features
Stratasysȱ3DȱprintersȱareȱdesignedȱtoȱcomplyȱwithȱCEȱandȱFCCȱstandards.ȱ
Theyȱareȱequippedȱwithȱtheȱfollowingȱsafetyȱfeatures:
Theyȱareȱequippedȱwithȱtheȱfollowingȱsafetyȱfeatures:
CoverȱInterlockȱ
Switch
TheȱpowerȱsuppliedȱtoȱtheȱUVȱlampȱandȱtheȱ
motionȱmotorsȱisȱturnedȱoffȱwhenȱtheȱcoverȱisȱ
opened.
WARNING:ȱDoȱnotȱdefeatȱ(override)ȱtheȱ
WARNING:ȱDoȱnotȱdefeatȱ(override)ȱtheȱ
interlockȱswitch.ȱDoingȱsoȱcouldȱresultȱinȱ
seriousȱpersonalȱinjury.ȱIfȱtheȱinterlockȱswitchȱ
doesȱnotȱfunctionȱcorrectly,ȱdoȱnotȱuseȱtheȱ
printer,ȱandȱcontactȱyourȱserviceȱprovider.
SafetyȱLock
Theȱcoverȱisȱlockedȱwhileȱtheȱprinterȱisȱ
working.ȱTheȱlockȱisȱreleasedȱwhenȱtheȱprinterȱ
revertsȱtoȱpauseȱorȱstopȱmode.
WARNING:ȱDoȱnotȱdefeatȱ(override)ȱtheȱ
WARNING:ȱDoȱnotȱdefeatȱ(override)ȱtheȱ
safetyȱlock.ȱDoingȱsoȱcouldȱresultȱinȱseriousȱ
personalȱinjury.ȱ
Ifȱtheȱsafetyȱlockȱdoesȱnotȱfunctionȱcorrectly,ȱdoȱ
notȱuseȱtheȱprinter,ȱandȱcontactȱyourȱserviceȱ
provider.
UVȱScreeningȱ
Theȱtransparentȱsectionȱofȱtheȱcoverȱblocksȱ
harmfulȱUVȱradiation,ȱallowingȱtheȱoperatorȱtoȱ
viewȱtheȱmodelȱasȱitȱisȱbeingȱmade.
CircuitȱBreaker
Theȱpowerȱtoȱtheȱprinterȱisȱturnedȱoffȱinȱcaseȱofȱ
electricalȱovercurrent.ȱ
Note: The circuit breaker is only accessible to
service personnel.
service personnel.
UVȬLampȱ
Overheatingȱ
Protection
TheȱpowerȱsuppliedȱtoȱtheȱUVȱlampȱandȱtheȱ
motionȱmotorsȱisȱturnedȱoffȱifȱtheȱtemperatureȱ
aroundȱtheȱlampȱreachesȱ90ȱ°Cȱ(194ȱ°F).ȱ
A label onȱtheȱUVȬlampȱcoverȱindicatesȱifȱtheȱ
temperatureȱhasȱexceededȱ65ȱ°Cȱ(150ȱ°F).
GroundedȱChassis
Theȱchassisȱofȱtheȱprinterȱisȱgrounded,ȱtoȱ
preventȱelectricalȱshock.
Note: The power outlet must be properly
grounded, in accordance with the local
electric code, to provide this protection.
grounded, in accordance with the local
electric code, to provide this protection.
UV screen
If the Stratasys 3D printing system is not used as specified in this guide, the
safety features may not provide adequate protection.