Configuring the MDC-2
 
The  MDC-2  is  normally  shipped  pre-configured  for  most  applications.  Actual  device  configuration  is 
beyond the scope of this manual and is more properly covered in the mist™ Mesh Network Operator’s 
Manual. Configuration is done using mist Network Management Protocol (MNMP) commands. MNMP is 
analogous to standard Internet Simple Network Management Protocol (SMNP). 
Configuration and software upgrades are performed over-the-air using the mist™ Mesh Network. 
4.1  Resetting Device Parameters 
When  a  device  is  not  joined  to  a mist™  mesh  network, over-the-air configuration management  is  not 
possible. In some  cases  the  node  cannot  rejoin the network because  of prior erroneous configuration 
changes  made  using  MNMP.  Some  MNMP  variables  might  be  preventing  the  device  from  joining.  For 
this and all other cases where a device must be reset to factory parameters while off the network there 
is a manual method: 
1.  Apply the magnet to the side of the MAT for 4 seconds. There will be 1 second green LED blink in 
the beginning of these 4 seconds.  
2.  Remove  magnet  for  4  seconds.  As  soon  as  you  remove  the  magnet  you  will  see  sub-second 
green and then orange blinks. 
3.  Reapply magnet for 1 second you will see sub-second green and then orange blinks again. Then 
after 1-2 seconds pause you will see orange LED going solid for ~10 seconds. This is an indication 
of the successful NVS reset. 
4.  If it did not work wait for 10 seconds and repeat the whole sequence. 
This  procedure  restores  all  device  parameters  to  their  software  defaults  and  it  causes  the  device  to 
reset. This procedure does not erase the persistence memory storage. 
5  Troubleshooting 
5.1  Mesh Network Issues 
The  majority  of  MDC-2  issues/questions  are  related  to  network  connectivity.  If  the  MDC-2  is  blinking 
green, the device is seeing and has joined a valid, authenticated mesh network. But if messages from the 
device  are  not  being  received,  this  likely  means  that  the  gateway  device  that  is  operating  the  mesh 
network  is  not  communicating  to  your  Device  Management  Center  (DMC).  Remember  that  a  MDC-2 
joins  the  first  network  that  it  sees,  but  the  tag  will  continually  look  for  a  “better”  network.  Also 
remember that messages pass from tag to tag on the way to the gateway. If tags are physically removed 
from the network they may carry messages with them. 
The  best  way  to  resolve  a  mesh  network  connection  issue  is  to  remove  the  tag  in  question  to  an 
isolated, known good mesh network. 
5.2  Battery Issues 
The  normal  MDC-2  configuration  will  yield  a  battery  life  of  at  least  1  year  per  battery.  The  MDC-2  is 
normally equipped with 3 Lithium A-Cells and so a 3+ year battery is expected. Extended duration high 
temperature  operation  (50C  or  greater)  will  reduce  battery  life.  Extended  duration  low  temperature 
operation (0C or lower) will reduce battery life.