DAMALL TECHNOLOGIES SAS D-2304 ユーザーズマニュアル

ページ / 39
D
AMALL 
IP
 
P
HONES
 
 
U
SER 
M
ANUAL
 
 
P
AGE 
|
 
26 
 
 
In the text field, enter the desired rule and click ‘Add’ to save it. Use the syntax 
code explained in the table below set new rules. See the examples given for further 
clarification. 
 
 
Rule Examples: 
365 
When dialling 365 the ATA immediately starts a call to the number 
without any delay. This means that it is not be possible to make 
any calls to numbers that start with 365.  
365T2 
Same as the above example, but which only dials the number after 
a 2 second delay to avoid conflicts. It is important to add a timeout 
at the end of this rule so that the ATA will start a call if no digits 
are entered. 
[18]xxx   
Any four digit numbers between 1000 and 8999.  
9xxxxxxx 
Any 8 digit numbers starting with 9 
 
All rules entered are displayed in the Digital Map Table. To delete a rule select it 
from the drop down menu and click ‘Delete’. 
 
 
 
Any digit between 0 and 9 
[ ] 
A range of numbers 
This must be defined either by using the min/max or by 
listing the digits separated by commas. Examples: 
[1,5,9] means only 1, 5 and 9 are allowed 
[15] means all numbers between 1 and 5 
T(n) 
Determines the delay time after which a call is started 
following the last key pressed.  
The value (n) is expressed in seconds, and must always 
be placed at the end of the rule.