2.4.11 Calculating the Maximum Output Power allowed
The regulatory limits for maximum output power are specified in EIRP (equivalent isotro
pic radiated power). The EIRP level of a device will be installation dependent and final c
onfiguration is the responsiblity of the professional installer. However in general the fin
al EIRP can be calculated by adding the gain of the antenna used (specified in dBi) to
the output power available at the connector (specified in dBm) minus any cable loss.