5.7 GUI Status
The status page display system, control, and alarm information.
When you set any value on the Control page the change will be reflected on Status page.
When you set any value on the Control page the change will be reflected on Status page.
<Status>
5.7.1 System
• Firmware version and location are displayed under Equipment Information.
• The current band setting, set from the control page, is shown in bold font.
• The current band setting, set from the control page, is shown in bold font.
5.7.2 Operating
• DL Path Monitor displays input from the donor antenna circuit, output power at equipment
server antenna port, and downlink amplifier gain.
• UL Path Monitor displays input from the server antenna circuit, output power at equipment
donor port, and uplink amplifier gain.
• Isolation Status shows isolation value (dB) between the donor antenna and server antennas.
• Available gain allowed by isolation measurement. Available gain is derived from the
• Available gain allowed by isolation measurement. Available gain is derived from the
antenna isolation value plus 15dB. Full system gain (43dB) is available if the antenna
isolation value is at least 58dB.
isolation value is at least 58dB.
5.7.3 Alarm
• If an alarm occurs, the alarm LED on the equipment will turn on.