Plugging Up The System 
 
The
  XONE:464  uses  professional  grade  3  pin  XLR,  1/4"  TRS  jack  and  RCA  PHONO 
sockets.    To  ensure  best  performance,  we  recommend  that  you  use  high  quality  audio 
cables and connectors, and take time to check for reliable and accurate cable assembly.  
It  is  well  known  that  most audio  system failures  are  due  to  faulty  interconnecting  leads.  
The following mating plugs may be used to connect audio signals to the console: 
 
All  input  and  output 
XLR  connectors  are  3  wire  differentially  balanced.    These  have  3 
connector pins:  Pin 1 = ground (screen), Pin 2 = signal hot (+), Pin 3 = signal cold (-). 
All  the  jack  sockets  are  the  3  pole 
TRS  type.    These  are  wired  to  work  with  both  the 
balanced  TRS  or  the  unbalanced  2  pole  TS  type  plugs.  The  sockets  have  3  connector 
pins:  Inputs and outputs are Tip = signal hot (+), Ring = signal cold (-), Sleeve = ground 
(screen).  Insert connections are Tip = send, Ring = return, Sleeve = ground. 
The 
RCA  phono  connectors  are  the  2  wire  unbalanced  type  typical  of  those  found  on 
equipment such as CD players, turntables and domestic amplifiers. 
Avoid reversing + and - on balanced connections as this will result in out of phase signals 
(reverse polarity) which may cause signal cancellation effects.  
For live work where long cables runs are required, balanced interconnections should be 
used.    However,  interconnections  between  more  affordable  2-wire  (signal,  ground) 
unbalanced equipment and the console are unlikely to cause problems if the cables are 
kept short.  Refer to the following diagram for unbalanced to balanced connections. 
 
Dealing with Ground Loops, Buzz and Interference 
For  optimum  performance  all  audio  signals  should  be  referenced  to  a  solid,  noise-free 
ground (earth) point, frequently referred to as the ‘star point’ or ‘clean earth’. 
A ground loop is created when the signal has more than one path to ground.  Should you 
experience  hum  or  buzz  caused  by  ground  loops,  check  first  that  each  piece  of 
equipment  has  its  own  separate  path  to  ground.    If  so,  operate  ground  lift  switches  on 
connected  equipment  in  accordance  with  the  instruction  manuals.    Alternatively 
disconnect the cable screen at the destination end only.  This breaks the offending loop 
while still maintaining the screening down the length of the cable. 
 
WARNING   For your safety do not remove the earth (ground) connection in the 
power lead of the console or connected equipment.  
To avoid interference pickup keep audio cables away from mains power units and cables, 
thyristor dimmer units or computer equipment.  Where this cannot be avoided, cross the 
cables at right angles to minimise interference.