Allen & Heath Xone:464 XONE 464 ユーザーズマニュアル

製品コード
XONE 464
ページ / 37
XONE:464 User Guide 
19 
Connecting the Headphones and Local Monitor 
L
TIP = L
RING = R
LOCAL MONITOR
R
 
LOCAL (BOOTH) MONITOR OUTPUTS   A pair of 3 pole TRS jack sockets provide left 
and right outputs from the console local monitor system.  These are impedance balanced 
and can be connected to balanced or unbalanced equipment as shown above.  Nominal 
operating  level  is  –2dBu  but  gain  is  available  to  drive  +4dBu  if  required.    Independent 
control  is  provided  for  the  local  and  the  headphones  monitor  systems.    This  output 
typically feeds the DJ booth monitor with the music only mix, and Cue if required. 
HEADPHONES  2 OUTPUT   Two outputs  are  available for stereo headphones, one on 
the front panel, the other on the rear panel.  This is convenient for permanent installation 
or when two headphones are required at the same time, for example presenter and guest 
in  a  broadcast  application.    The  same  signal  is  available  from  both.    Headphones  are 
available in many different styles, impedances and volume ratings.  To get the best from 
your  system  we  recommend  that  you  use  high  quality  closed  ear  headphones  in  the 
range 30 to 600 ohms.  8 Ohm headphones are not recommended. 
  WARNING      Some  headphones  are  more  sensitive  than  others  and  can 
produce  higher  output  levels.    To  avoid  damage  to  your  hearing  start  with  the 
PHONES  level  control  at  minimum  and  turn  up  only  as  much  as  is  needed  to 
maintain  comfortable  listening  level.    Do  not  drive  headphones  at  high  listening 
levels for long periods of time. 
 
User Connector Options 
SYS-LINK OUT
(option)
(user connections)
REMOTE
SYS-LINK OUT
(option)
(user connections)
REMOTE
 
SYS-LINK OUTPUT   The console is supplied with a blank plate fitted here.  An optional 
kit of parts is available to install a 25 pin D-connector and circuit card which provides all 
console  outputs  on  a  single  connector.    This  is  convenient  when  connecting  the 
XONE:464  as  an  expander  to  another  console.    Use  a  standard  25  pin  one-to-one 
shielded  cable  to  plug  this  output  into  any  Allen  &  Heath  console  fitted  with  SYS-LINK 
input.  Alternatively wire a custom cable as required.  SYS-LINK operates unbalanced at 
–2dBu and is not intended for long cable runs.  Note that SYS-LINK input is not available 
on the 
XONE:464.  Contact your Allen & Heath agent for further details. 
USER CONNECTOR   The console is supplied with a blank plate fitted here.  A 25 pin D-
connector may be installed and custom wired to satisfy the particular requirements of the 
application.    The  installation  of  this  connector  should  be  carried  out  only  by  qualified 
personnel.  Contact your agent for further details.