4.0 Mounting
When mounting the Nano Prox Proximity Reader please
respect the following guidelines.
• Avoid wiring the Nano Prox cables in the same conduit
with AC power cables, lock power, or signal wiring.
• Maintain all reader wiring a minimum of 12" (30cm)
away from other wiring such as AC power, computer
data wiring, telephone wiring and wiring to electric lock
devices.
data wiring, telephone wiring and wiring to electric lock
devices.
• Avoid installing within 3.5 feet (1.1m) of computer
monitors or CRTs. The minimum distance will vary
depending on the type of monitor or CRT.
depending on the type of monitor or CRT.
• Avoid installing in proximity to sources of broad
spectrum EMI noise such as motors, pumps,
generators, DC to AC converters, uninterruptible power
supplies, AC switching relays, light dimmers, computer
monitors and CRTs.
generators, DC to AC converters, uninterruptible power
supplies, AC switching relays, light dimmers, computer
monitors and CRTs.
• Avoid installing in proximity to potential sources of high
power RF signal transmitters such as cellular
telephones and two way radios.
telephones and two way radios.
5.0 Wiring Connection
Two wiring methods can be used. Dual LED operation
allows the signalling of both LED's independently using the
LED control lines. Single LED allows a single LED line to
control both LED colours.
Figure 1 - Dual LED Connection
Figure 2 - Single LED Connection
Using the recommended cables listed in the technical
specifications in section 7, splice these cables together
with the pigtail of the reader and seal the splice. Route the
cable from the reader to the host controller. Connect the
cables as shown in Figure 1 for Dual LED Operation or
Figure 2 for Single LED Operation.
Do not connect the shield wires together at the
reader cable splice. With the shield wire
already terminated at the reader terminate the
shield at the controller. For more information
refer to Figure 1 and Figure 2.
6.0 Button Input Wiring Connection
Button input wiring configuration is shown in Figure 2. For
programming options refer to the Protégé System Manual.
Figure 3 - Button Input Wiring
Connect a normally open button or switch as shown in
figure 2 and complete the programming within the Protégé
Integrated System for the functionality required.
External Button Input Mode and single LED
operation must be enabled when using this
wiring configuration.
7.0 Specifications
Power Supply
Voltage
12VDC (9.5 - 14.0VDC)
Current
120mA (Peak, Reading)
Read Range
Card
Up
to
10cm
(4")
Tag
Up
to
6cm
(2.5")
Interface
Wiegand
Multiple Format 26, 34, 37 Bit
Data 0 and Data 1
Distance
150 Meters (500 feet)
Frequency
Field
125KHz
Pulse
Width
Modulated
Cable
Type
Multi Conductor 22Awg Alpha 5196, 5198
18Awg
Alpha
5386,
5388
18Awg
Beldon
9553
Temperature
Operating
Operating
-35˚- +65˚ Celsius
-31˚ - 149˚ Fahrenheit
*Specifications are subject to change without notice,
please visit www.integratedcontroltechnology.com for the
updated information. Read range is specified using an ICT
card format and the card is presented parallel to the
reader using installation procedures detailed in this
manual without any electrical interference present.