82  |  Managing the Radio 
 
 
Aprisa SR User Manual 
 
Terminal > Parameters 
The  Parameters  page  is  a  dynamic  page  that  will  display  the  parameters  associated  with  the  active 
alarms,  set  on  ‘Events  >  Events  Setup’  on  page  137.  The  screenshot  below  shows  a  small  amount  of 
monitored alarms as an example. 
 
 
 
The following is a list of alarm events that are monitored: 
 
Monitored Parameter 
Unit 
Event ID 
Event Display Text 
Current Temperature  
Celsius 
Temperature Threshold 
Last RX Packet RSSI 
dBm 
RSSI Threshold 
Last Sample RX CRC Error  
Ratio 
RX CRC Errors 
Last Sample RF RX Data  
Count 
34 
RF No Receive Data 
Last Sample Eth1 RX Data  
Count 
10 
Port 1 Eth No Receive Data 
Customer Eth1 Data RX Errors  
Ratio 
11 
Port 1 Eth Receive Errors 
Customer Eth1 Data TX Errors  
Ratio 
12 
Port 1 Eth Transmit Errors 
Last Sample Eth2 RX Data  
Count 
35 
Port 2 Eth No Receive Data 
Customer Eth2 Data RX Errors  
Ratio 
36 
Port 2 Eth Receive Errors 
Customer Eth2 Data TX Errors  
Ratio 
37 
Port 2 Eth Transmit Errors 
Last Sample Serial RX Data  
Count 
13 
Serial Data No Receive Data 
Customer Serial Data RX Errors  
Ratio 
14 
Serial Data Receive Errors 
Last TX Packet PA Current  
mA 
None 
 
Last TX Packet AGC 
mV 
None 
 
Last TX Packet Reverse Power 
dB 
None 
 
Current RSSI 
dBm 
None 
 
If  an  associated  alarm  event  occurs,  the  Parameters  table  will  display  the  current  value  for  that 
parameter. The refresh time is 12 seconds.