Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル
SIP-DECT OM System Manual
314
The alarm trigger “LOC-ERR-USERSTATE” is handled like SOS (
), ManDown (
) but no voice call
will be established.
The alarm trigger “LOC-ERR-USERSTATE” will be displayed as a Customer specific event (
).
7.29.6 LICENSING AND SYSTEM CAPACITIES
The “User monitoring” feature does not require a specific license. However, if the OM Locating
application is used to receive the OML specific alarm trigger “LOC-ERR-USERSTATE”, the OML
application license (OM Locating Server License) must be available.
application is used to receive the OML specific alarm trigger “LOC-ERR-USERSTATE”, the OML
application license (OM Locating Server License) must be available.
The number of monitored users is limited, as follows:
RFP OMM
•
Passive monitored users: 30
•
Active monitored users: 20
PC OMM
•
Passive monitored users: 300
•
Active monitored users: 200
An OMM system health state will be set if the number of monitored users exceeds the system
capabilities. In this case also an associated health state alarm trigger will be generated.
capabilities. In this case also an associated health state alarm trigger will be generated.
7.29.7 CONFIGURATION
User monitoring can be administered via the OMP.