Mitel Deutschland GmbH 68635RFP36U-01 ユーザーズマニュアル
SIP-DECT OM System Manual
52
5 OMM WEB SERVICE
The OMM acts as an HTTP/HTTPS server. The HTTP server binds to port 80 and HTTPS binds to port
443 by default. A HTTP request on port 80 will be redirected to HTTPS on port 443.
443 by default. A HTTP request on port 80 will be redirected to HTTPS on port 443.
5.1 LOGIN
The OMM allows more than one user at a time to configure the system. A user must authenticate with a
user name and a password. Both strings are case-sensitive.
user name and a password. Both strings are case-sensitive.
With initial installation, or after discarding all settings, the OMM Web service is accessible via a default
built-in user account with user “omm” and password “omm”.
built-in user account with user “omm” and password “omm”.
With the first login to a new SIP-DECT software version, the user must accept the End User License
Agreement (EULA) (see section 5.11).
Agreement (EULA) (see section 5.11).
If the default built-in user account is active, the administrator must change the default account data
(passwords) of the “Full access” and “root” account. The meaning of the different account types is
described in section 7.17.1.
(passwords) of the “Full access” and “root” account. The meaning of the different account types is
described in section 7.17.1.
Please note:
The OMM forces a change to the default account data. As long as the
passwords are unchanged, the OMM will not allow any other configuration.